Tracking Test Apparatus

Author: Released in:2024-03-21 Click:67

Tracking Test Apparatus

Tracking Test Apparatus

Compliant with standards:

GBT 4207, IEC 60112 (2003), IEC 60745-1, IEC 60335-1, IEC 60598-1, IEC 60884-1

Applicable scope:

Suitable for research, production, and quality inspection departments applicable to lighting equipment, low-voltage electrical appliances, household appliances, machine tool appliances, motors, electric tools, electronic instruments, electrical instruments, and information technology equipment, as well as insulation materials, engineering plastics, electrical connectors, and accessory industries.

Product details:

1. The leakage trace tester is a specialized testing instrument developed, designed, and manufactured in strict accordance with standards such as GB4207 and IEC60112,

2. Simulating the measurement of leakage marking index and leakage resistance marking index under humid conditions has the characteristics of simplicity, accuracy, reliability, and practicality.

3. The electrochemical tracing index test is conducted on the surface of solid insulation materials, applying a certain voltage between platinum electrodes of a specified size (2mm x 5mm) and dropping a specified volume of conductive liquid (0.1% NH 4 CL) at a fixed height (35mm) for 30 seconds to evaluate the leakage resistance performance of the surface of solid insulation materials under the combined action of an electric field and humid or polluted media.

Structural features:

1. Spray painting treatment of combustion chamber; Beautiful and elegant, corrosion-resistant; Size: 1200mm X 600mm x 1200mm;

2. All sample racks are made of stainless steel material;

3. The equipment consists of a voltmeter, ammeter, delay overcurrent relay, power supply, circuit control system, button switch, signal light, etc;

4. The automatic droplet device includes a droplet cylinder, droplet nozzle, counting device, droplet counting device, droplet control device, droplet volume measuring tool, etc;

5. The drip nozzle device is adjustable; Adjust the height to 30-40mm; Ensure that the dripping position is between the two electrodes;

6. The electrode device includes platinum electrodes, electrode fixing devices, 4mm gauges, etc. The electrodes are adjustable and detachable;

7. The electrode is 5mm wide, 2mm thick, 99.9% pure platinum, with a pointed tip of 30-60 degrees;

8. The pressure of the electrode on the sample is adjustable, with an adjustment range of (1.00N ± 0.001N); Electrode distance 4.0mm ± 0.01mm, included angle 60 ° ± 5 °;

9. Equipped with a sample stage;

10. Equipped with glass panels: thickness ≥ 4mm;

11. Equipped with electrolytes: one bottle of ammonium chloride and one bottle of sodium alkylnaphthalene sulfonate reagent each;

Security control system:

12. Test voltage: 0~1000V continuously adjustable digital display, maximum error of voltmeter display value: 1%;

13. Short circuit current: (1 ± 0.) 1) A. The voltage drop value shall not exceed 10%;

14. If the test current exceeds 0.5A for more than 2 seconds, the system will automatically shut down the equipment;

15. Safety door control system; When the door is opened, the test system cannot function;

16. Electrodes: One pair of 5mm x 2mm rectangular platinum electrodes and one pair of brass electrodes, in accordance with the size requirements of Figure B.1 of IEC60112;

17. Electrodes: The angle between the electrodes is 60 ° ± 5 °, with a spacing of (4 ± 0.1mm);

18. Electrode: The pressure on the sample is: 1 00N ± 0.05N;

19. Dropping system: (30 ± 5) seconds (starting dripping time 29.8 seconds+starting dripping duration 0.2 seconds) automatic counting and digital display (preset), 50 drops time: (24.5 ± 2) minutes;

20. Dropping system: The height from the tip of a droplet needle to the surface of the sample is 35mm ± 5mm (with a gauge attached for measurement reference);

21. Dropping system: Dropping weight: 20 drops: 0.380g~0.489g; 50 drops: 0 997g~1 147g;

22. PLC combined with touch screen control system; Realize more intelligent and convenient experimentation;

23. The experimental data is automatically recorded, stored, and can be freely accessed.

Technical parameters:

1. Electrode material: electrode head - platinum metal (platinum)

2. Electrode pressure: 1.0 ± 0.05N

3. Electrode distance: 4.0mm ± 0.01mm, included angle 60 ° ± 5

4. Electrode voltage: 100-600V (48-60HZ) adjustable, voltage drop less than 10% when short-circuit current is 1.0 ± 0.1A

5. Droplet height: adjustable from 30 to 40mm

6. Droplet size: 44-55 drops/1cm3 adjustable

7. Dropping time: 30s ± 5s

8. Dropping frequency: 0~9999 adjustable times

9. Leakage judgment: If the circuit current is greater than 0.5A and maintained for 2 seconds, the relay will act to cut off the current, indicating that the sample is unqualified

10. Test process: Automatic control of the test program, independent ventilation

11. Reference standards: IEC60112, GB/T4207, GB4706.1

12. Studio volume: 0.1m3 (customizable to 0.5 m3 or 0.75m3)

13. External dimensions of equipment: 630mm wide x 390mm deep x 750mm high

Notes:

1. During the operation of the leakage trace tester, personnel should pay attention to personal protection to avoid injury caused by leakage or contamination of the mouth and eyes by the solution.

2. Input power AC220 ± 2%.

3. When testing the sample, do not open the compartment door. After the test is completed or when the experiment fails and produces smoke, first turn on the fan to eliminate smoke, and then open the compartment door for operation

4. The exhaust pipe should run out of the window.

5. The power supply should be equipped with a three pole socket with a ground wire to ensure reliable grounding.

6. Before the experiment, it is necessary to confirm whether the equipment is within the measurement validity period. If it exceeds the validity period, the experiment cannot be conducted.