Product introduction
Scope:
Eyeglasses Frame Testing Machine is designed and developed according to the National Standards of the People\'s Republic of China GB/T14214-2003, GB13511-1999 General Requirements for Eyeglasses Frames and Testing Methods Chapter 9 Requirements of the Automatic Pulling Force 98.0 N and show the automatic testing equipment.
Aim of the test: To determine that the connecting part of the frame has a certain tensile function, to prevent the frame from being damaged by tension and pressure, and to ensure that the frame lasts 2 years or more longer normal and safe use. The focus is on solder joints and non-welded joints that require major inspections.
Reference standards: GB/T14214, GB13511, ISO12870, etc.
Eyeglass frame testing machine According to the standard GB/14214-2003 \"General requirements and test methods for spectacle frames\" and ISO12870:1997 \"Ophthalmic optics - spectacle frames - basic requirements and test methods\"
Technical parameters:
Instrument model: FLR-Y07 Eyeglasses frames test machine
Example: 1 set of spectacles frames
Fixture: Provide different fixtures, which can separate mirror rings, metal frames, plate frames, etc. to test.
Measuring range: 100N, 200N, 500N optional
Range accuracy: 0.01N
Test unit: kg, N, LB can be converted
Volume: 420x420x1000mm
Weight: 50kg
Power supply: AC220V 50Hz
Test method:
1. Use the fixture to clamp the frame according to the requirements (because the specific test content is different, the position of the fixture is different);
2. Set the parameters (lifting speed, tension value, etc.)
3. Start the instrument and stup after the instrument automatically and slowly apply the tension to 98N;
4. Observe the condition of the frame, each There should be no bad phenomena such as breakage and falling.
Note:
Metal eyelets Frame: Clamp the two legs with the fixture 20 mm from the center of the hinge and move in opposite directions. When the specified value is reached, remove the frame to observe the damage.
Plastic frame and natural organic material frame, fix the front frame within 5mm of the hinge, make the temples vertical to the front frame and clamp the temples at a distance of 30 mm from the front frame, apply force in the direction of the temples, when the force reaches the specified value, remove the transom Check the condition of the hinges and connectors. Repeat the above test on the sample\'s other temple.