Welcome to the Qinsun Instruments Co., LTD! Set to the home page | Collect this site
The service hotline

Search


Related Articles

Product Photo

Contact Us

Qinsun Instruments Co., LTD!
Address:NO.258 Banting Road., Jiuting Town, Songjiang District, Shanghai
Tel:021-67801892
Phone:13671843966
E-mail:info@standard-groups.com
Web:http://www.qinsun-lab.com

Your location: Home > Related Articles > Precautions for use of ICI Rolling Box Pilling Tester

Precautions for use of ICI Rolling Box Pilling Tester

Author: Released in:2022-12-05 Click:39

Product Description:

ICI Rolling Box Pilling Tester is used for rolling friction pilling testing of carded fabrics made from fine wool and other easily pilling fabrics to evaluate their performance under unsolicited conditions. Next degree of pilling. It is a universal pilling test system with 2 or 4 probes which can quickly simulate fabric pilling within a certain period of time under normal wearing conditions.

Detection principle:

When detecting, the cylindrical sample is placed on the drum with placed on the surface of the sample using a hammer nail hanging on a chain. When the drum rotates at a constant speed, the hammer rotates and bounces randomly on the sample surface and hooks the sample, causing the sample surface to stick. Compare by numberof turns specified on the standard sample to assess the degree of stickiness of the sample. Two stations, four stations optional.

Complies with standards:

GB/T4802.3, ISO 12945.1, BS5811, JIS L1076, IWS TM152 Technical parameters:

1. Number of pilling boxes: 4;

2. Box size: 235×235×235mm;

3. Box speed: 60±2r/min;

4 Count range: 1-99999 times;

5. Sample loading tube: Φ31.5×140mm shape, 4 pcs /box;

6. Power supply: AC 220V ±10% 50Hz 120W.

Manual Instructions:

Put the 105mm × 105mm samples into the test box. Under the rotation of the wheel, the cork liner of the storage box will continue to rub randomly, set the timer to the specified time, and when the set time is reachedint, a continuous tone sounds indicating that the test is complete. During the test wird compressed air blown into the test chamber to improve rotation, and the air pressure can be adjusted.

Notes:

1. If the average of the experiment is not a whole number, change it for the next half step.

2. The difference in the evaluation results of each sample should not exceed half a score, otherwise the score of each sample will be reported separately.

3. If a new cork insert is installed in the roller box, it must be inserted into an empty tube for operation after 200 hours.

4. The cork pad can be cleaned with a little denatured alcohol.

Prev:

Next: