Circular Track Pilling Tester uses a linear guide rail as a sliding gauge to test the pilling condition of wool fabrics, pure cotton, synthetic cotton, blended, knitted and woven fabrics. To identify product quality and process effect. Next, Shanghai Qianshi brings you the circular orbit method pilling tester test analysis.

Principle of the test:

Perform with a nylon brush and an abrasive or disposable abrasive Compare after rubbing and Pilling, then under the specified lighting conditions, the pilling pattern with the standard photo to assess the degree of pilling.

Main parameters:

1. The contact space between the grinding head and grinding table: ≤ 0.2 mm;

2. Parallelism between grinding head and grinding table: ≤0.3 mm;

3. Grinding head and grinding table The relative BeTrajectory of movement of the grinding table: 40±1mm; p>

4. The surface of the nylon brush is flat and the height difference is less than 0.5mm;

</ p

5 .Grinding table reciprocating speed: 60±1 times/min;

6. Grinding head weight: 490cN±1%;

7. Big hammer weight: 290 cN±1%;

8. Small heavy hammer weight: 100 cN ±1%;

9. Time selection: 1——9999.

Pilling test:

1. Set the counters according to GB4802.1-97 .

2. Take the sample and fix it correctly and firmly in the sample holder.

3. Place the specimen holder so that the specimen touches the grinding plane.

4. Press the \"RUN\" button to make the instrument perform pilling.

5. After automatic shutdownic of the machine, rotate the sample chuck and remove the sample after grinding for evaluation.

Lint Test:

1. Take out the sample and squeeze it tightly in the chuck. Adjust the friction ion times for the counter according to GB/T4802.1-97.

2. Select the sample weight according to the regulations in case you need additional weight. With an additional weight, the required weight can be clamped onto the clamp shaft.

3. Place the specimen holder so that the specimen is in contact with the plane of the brush.

4. Press the \"RUN\" button, the instrument can run according to the set number, and the instrument will stop automatically when the set number is reached.