Germany Testo 300 Flue Gas Analyzer
Product introduction
testo 300 flue gas analyzer is suitable for the heating system testing industry, testo\'s decades of experience in measurement technology and modern intelligent touch operation, combined with processing power, can send record reports by e-mail. Flue gas, draft, differential pressure, ambient CO and temperature differences can be easily measured with the testo 300and. TÜV certified, complete with O2, CO sensor with H2 compensation (measuring range 0 to 8,000 ppm), basic flue gas probe, instrument case and practical accessories.
Product Features
1. Use smart touch technology flue gas analyzer
O2 and CO sensors (0 ~ 8,000 ppm)
No sensor can be installed
Longer sensor life with automatic sensor protection
TÜV certified according to FER1 and EN 50379, parts 1-3
Integrated micro pressure measurement
Multi-function handle and quick probe change: You benefit from the multi-function handle for mounting different probe sheaths (to be ordered separately), e.g. for use with trachea with special diameters Long probe sheaths or flexible probes that are difficult to reach the measuring point
Optional probes and accessories are suitable for more measurement tasks, such as airflow pressure measurement, flue gas duct inspection, temperature difference measurement, ambient CO measurement
2. Intelligent, intuitive and efficient: easy to operate in daily work
Smart touch display reacts instantly and without any delay. Intuitive operation - as easy as a smartphone
FasterGet measurement results: clearly structured measurement menu for all relevant measurements
Easy creation of records on location (including measures, measurement locations and customer details)
Save the measurement record directly to theinstrument op
signature function: your customers can sign the measurement report directly in the instrument
Email measurement data via WLAN (hotspot) directly to the office or to customers
Large 5-inch HD screen to view system parameters directlyview
testo interface function for direct data transfer, measurement value transfer to industry -/custom software*
No need to wait, in standby mode press just click the button and you can measure
Smart Bluetooth interface: connect to a Bluetooth printer on site, and print the measured value directly
Rechargeable battery , up to 10 hours battery life
Integrated strong magnet for easy fixation during the measurement
Product parameters
Type K (NiCr-Ni)
measuring range
-40 ~ +1200 °C
measurement accuracy
±0.5 °C (0.0 ~ +100.0 °C)
±0.5% of measured value (rest of range)
resolution
0.1°C (-40 ~ +999.9°C)
1 °C (other ranges)
Differential pressure
Measuring range
-100 ~ +200 hPa
Measurement Accuracy
±0.5 hPa (0 ~ + 50.0 hPa)
±1 % reading (+50.1 ~ +100.0 hPa)
±1.5 % of measured value (+100.1 ~ +200 hPa)
resolution
0.01 hPa
O?measure
measuring range
0 ~ 21 Vol.%
Measurement accuracy
±0.2 Vol .%
CO (H? Compensation)
measuring range
0 ~ 8000 ppm
Measurement accuracy
±10 ppm or ±10 % of measured value (0 ~ 200 ppm)
±20 ppm or ±5 % of measured value (201 ~ 2000 ppm)
±10% of measured value (2001 ~ 8000 ppm)
resolution
1 ppm
Tractive force measurement
measuring range
-9.99 ~ +40 hPa
measurement accuracy
±0.005 hPa (0 ~ 0.1 hPa)
±0.02 hPa (0.1 ~ +3.00 hPa)
±1.5 % of measured value (+3.01 ~ +40 hPa)
resolution
0.001 hPa (0 ~ 0.1 hPa)
0.01 hPa (other ranges)
Validation
measuring range
0 ~ 120 %
resolution
0.1 %
Smoke Loss
measuring range
0 ~ 99.9%
resolution
0.1 %
CO? measurement (calculated by O?)
measuring range
Display range 0 ~ CO? max
measurement accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
CO environmental measurement
measuring range
0 ~ 2000 ppm
measurement accuracy
±10 ppm (0 ~ 100 ppm)
±10% of measured value (101 ~ 2000 ppm)
resolution
1 ppm
Technical parameters
Operating Humidity
15 ~ 90% RH non-condensing
diameter
244 (including probe connection) x 98 x 59 mm LxWxH
Operating temperature
-5 ~ +45 °C
Protection, etc.*
IP40
memory
1,000,000 measurements
Storage temperature
-20 ~ +50 °C
weight
about 800 g